Abrites adapters for connecting the AVDI straight to a removed VAG instrument cluster, both VDO and Micronas types, without having to refit it in the car. They are used for cluster reading and calibration work on the bench.
⚠ WarningThe ZN059 (VDO) and ZN060 (Micronas) mini DB adapters must be powered by the ZN063 - 12V/1A DC power adapter: use the specified one, not a generic power supply.
Procedure
Remove the instrument cluster and identify the type: VDO or Micronas, and for Micronas tell the new connector apart from the old one.
For a VDO cluster fit the ZN059 - VAG VDO cluster adapter.
For a Micronas cluster with the new-style connector fit the ZN060 - VAG Micronas (new style connector) cluster adapter.
For a Micronas cluster with the old connector fit the ZN061 - old-style Micronas cluster adapter.
Power the ZN059 and ZN060 with the ZN063 - 12V/1A DC power adapter.
Connect the adapter to the AVDI, start the Abrites software for VAG and open the instrument cluster section.
Read the cluster data first and keep a copy of it, then go ahead with the operation you need.
Reference screenshots
Source: Manuale AVDI - manuale comune, parte 2 di 2, adattatori ZN059-ZN063 (p.70-71) · ⏱ estimated time 20-40 min