Chip-Tools
Chip-Tools

Bench connection diagrams for MQB clusters with ZN058 Abprog

VAG Interface Classic Appendix Advanced ⏱ varies 3 steps

A collection of bench wiring diagrams for the most common types of MQB instrument cluster, which can be read with the ZN058 Abprog adapter.

Required licences

Hardware / cables

  • ZN058 Abprog

Procedure

  1. Identify which of the four most common MQB instrument cluster types shown in the manual you have.
  2. Wire the cluster on the bench following the matching diagram (diagrams 1 and 2 on page 124, diagrams 3 and 4 on page 125).
  3. Connect the ZN058 Abprog adapter as per the diagram and proceed with the read.

Reference screenshots

Bench connection diagrams for MQB clusters with ZN058 Abprog — 1Bench connection diagrams for MQB clusters with ZN058 Abprog — 2
Source: Manuale VAG (Offline), cap. 2.6 (p.124-125) · ⏱ estimated time varies
← All Abrites guides

More guides VAG