Meaning

The voltage of the upstream oxygen sensor (bank 1, sensor 1) stays too low. The ECU reads the signal as a constantly lean mixture or as a sensor circuit fault.

Common causes

  • Faulty or contaminated upstream O2 sensor
  • Short to ground in the sensor wiring
  • Genuinely lean mixture (air leak, low fuel pressure)
  • Corroded connector or intermittent contact
  • Exhaust leak ahead of the sensor

Symptoms

  • Check engine light on
  • Increased fuel consumption
  • Rough idle and hesitation
  • Possible smell of unburnt fuel

Severity

Moderate: the engine runs but with a non-optimal mixture; consumption and emissions rise and the catalytic converter may suffer over time.

What to do

  1. Read live sensor data and compare it with the downstream sensor
  2. Check sensor wiring and connector for shorts to ground
  3. Check fuel pressure and intake air leaks
  4. Replace the sensor if its signal stays low with correct fuelling

Format conversion

SAEP0131
HEX0131
VAG00305